Products

MOEORW-383K Insulating Suit Test Device Send email to us

Applications

Product Overview

Designed for power‑frequency hipot validation of live‑line protective gear, the MOEORW‑W383K integrated dielectric test bench streamlines routine lab assessments for insulating coveralls, rubber mats, insulating barriers and insulating blankets. Built in compliance with China power industry specification DL/T976‑2015, this consolidated testing workstation eliminates the need for scattered single‑function testers, cutting capital investment while delivering legally‑recognized test records for regulatory spot‑checks within power utilities.

Its unique soft composite electrode assembly adopts metal‑fiber woven fabric padded with fire‑retardant sponge. The conductive surface can closely conform to contoured PPE surfaces, avoiding surface scratches, indentations and material damage frequently caused by rigid metallic electrodes. It serves test labs, power‑supply corporations, third‑party inspection bodies and safety‑tool verification centers for insulating protective articles.

Application

1.Grid‑affiliated safety‑tool verification labs: execute periodic 6‑month or 12‑month hipot screening for field‑deployed insulating protective equipment.

2.Power generation & distribution enterprises: in‑house preventive dielectric verification for live‑maintenance insulating coveralls, mats and barriers.

3.Third‑party power‑product quality‑assessment institutes: generate valid hipot evidence and formal reports for PPE manufacturing vendors.

4.Insulating‑PPE manufacturers: carry out outgoing factory quality inspection for finished insulating suits and blankets prior to shipment.

5.Heavy‑industry high‑voltage workshop safety departments: scheduled verification for insulating mats and protective garments deployed within plant distribution switch‑rooms.

Features

Damage‑free pliable conductive electrodes Instead of hard metal plates, composite conductive cloth plus flame‑retardant sponge makes full surface contact with clothing‑style insulating PPE. Light misting over electrode surfaces optimizes heat dissipation during extended voltage‑holding cycles, preserving sample integrity throughout repeated dielectric trials.

Consolidated multi‑item test workstation One single bench completes four major test categories: insulating suit, insulating mat / blanket and insulating barrier hipot evaluations. Lab floor space and equipment procurement expenses can be greatly reduced by removing redundant discrete testers.

Robust, mobility‑oriented mechanical layout Full aluminium alloy framework fitted with lockable swivel casters supports convenient relocation and firm stationary positioning. Built‑in pull‑out drawers organize electrodes and high‑voltage cabling. A dedicated heavy‑duty grounding lug mitigates stray leakage risks during high‑voltage runs.

Full alignment with DL/T976‑2015 industrial protocol All testing workflows, hipot magnitude, voltage dwell duration and electrode placement strictly follow official preventive‑test codes for live‑working apparatus. Output test reports gain acceptance from grid‑run inspection authorities nationwide.

Segmented modular electrode architecture Partitioned electrode sets target chest, sleeves, trousers and shoulder sections of insulating suits; purpose‑built accessories serve mats, blankets and barriers. Regional segmented probing helps pinpoint local insulation defects that uniform large‑area electrodes may overlook.

Enhanced operator safety architecture Physically separated high‑voltage and ground circuits; removable top protective cover according to test requirements. Clear demarcated safety buffer zones lower flash‑over and electric‑shock hazards when voltage is applied.

Parameter

Electrical Ratings

Maximum hipot test voltage: 50 kV

Bench Dimensions & Construction

Overall footprint: 1800 mm × 1300 mm × 800 mm

Tabletop finish: Brushed aluminium alloy

Full Electrode Kit Supplied

Insulating coverall electrode groups

Inner‑outer electrode sets for insulating sleeves

Matched inner‑outer electrodes for insulating shoulder capes

Single inner electrode for chest section testing

Paired inner‑outer electrodes for insulating trousers

Reinforced edge test sheets (4 pieces: three 150×100 mm, one 50×150 mm)

Component Dimension & Description
Ground base plate Stainless‑steel worktop, 1300×1300×750 mm
Acrylic insulating sheet 1270×1270×5 mm, hollow central aperture of 762×762 mm
Conductive sponge mat 762×762×5 mm
High‑voltage aluminium electrode panel 762×762×5 mm

Insulating barrier surface‑test electrodes

Two metal test plates: 70 mm (L) × 30 mm (W)

Cylindrical electrodes for insulating blanket assessment

Item Geometry Parameters
Small cylinder Φ25 mm, height 25 mm, edge radius 3 mm
Large cylinder Φ75 mm, height 15 mm, edge radius 3 mm

After-sales guarantee

  • Free technical advice

    We provide you with free consultation services

  • On-site installation and commissioning

    Engineers provide guidance for installation and commissioning

  • Free training and maintenance

    Technicians can provide on-site maintenance services and receive regular training

  • Perfect after-sales services

    Perfect technical consulting service system

Workshop site

Video Center

Engineering Cases

Related products

Related articles

Send your message to us: