ME-OHLT10X Cable Oscillation Wave Partial Discharge Test System Send email to us

Applications

Equipment Introduction

     The cable oscillation wave partial discharge test system is a new type of testing equipment used for field detection and condition diagnosis of cables. It the characteristics of simplicity, practicality, small size, convenient transportation, non-destructive testing of cables under AC voltage conditions, and diversified insulation performance detection and evaluation means. system adopts a combination of damped AC voltage (DAC) withstand voltage test and partial discharge detection, which provides an effective means to discover potential defects in cable insulation

Features

The system can produce damped AC voltage of up to 30kV during the test, combined with advanced system hardware and system software for diagnosis, main technical features include:
Latest semiconductor technology;
Latest laser control technology;
Advanced digital signal processor and filtering technology;
Advanced wireless network control technology

Parameter

Serial number

project

Technical indicators

1

Power supply

220 VAC±10%, 50Hz

2

Oscillating wave output maximum voltage

30 kV (peak value)

3

Oscillation frequency range

20Hz ~500Hz

4

Test cable length range

200m~20km

5

High voltage charging current

10 mA

6

High-voltage switch

Triggering method: Laser-triggered high-voltage switch

7

 

High voltage switch control

On-time: 1µs

Switch on-resistance: less than 1Ω

Fiber optic communication

8

Partial discharge measurement range

1pC~100nC

9

Partial discharge level detection and bandwidth

Compliant with International Electrotechnical Commission (IEC) standard 60270

10

Partial discharge positioning bandwidth

150kHz~45MHz automatic adjustment

11

Partial discharge positioning measurement accuracy

1% of total cable length (minimum resolution 2 m)

12

Dielectric loss measurement range

0.1%~10%

13

Real-time sampling rate of partial discharge

100MHz

14

Partial discharge sampling storage depth

32MB (can record data length of 300ms )

15

Control method

Wireless control, wired control

16

Partial discharge calibration mode

Automatic/Manual

17

Boost mode

Programmable boost/manual boost

18

Time-domain pulse reflection positioning connector function in calibration mode

Automatic locking connector position

After-sales guarantee

  • Free technical advice

    We provide you with free consultation services

  • On-site installation and commissioning

    Engineers provide guidance for installation and commissioning

  • Free training and maintenance

    Technicians can provide on-site maintenance services and receive regular training

  • Perfect after-sales services

    Perfect technical consulting service system